bareos: master d518ff2b
Author | Committer | Branch | Timestamp | Parent | |
---|---|---|---|---|---|
master | 2013-07-09 11:25 | master e91fc068 | Pending | ||
Affected Issues | 0000200: Storage Daemon Tape Alert Useless / Defective | ||||
Changeset | Add config option for storing a diagnostic device. For some setups with an autochanger you might want to query the individual drives for tape alerts. As you cannot open the tape device twice you need to access the drive via a SCSI generic device. We now have a per device diagnostic device config variable which you can expand using a %D in the tape alert cmdline. Normally you should query the autochanger for tape alerts and that should also report any tape drive errors but some devices implement this poorly and as such it doesn't work. This option allows you to work around that and actually ask the drive for any tape alerts. Fixes 0000200: Storage Daemon Tape Alert Useless / Defective |
||||
mod - src/stored/stored_conf.h | Diff File | ||||
mod - src/stored/stored_conf.c | Diff File | ||||
mod - src/stored/sd_plugins.c | Diff File |